2154

Design for erecting a supporting, space-enclosing timber stud wall construction of fire resistance class F 30-B (REI 30) according to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation and inner and outer lining for one-sided fire exposure from the external wall side.

Construction ExampleProductThickness (mm)
InsideGypsum board ≥ 12,5


AGEPAN® OSB 3 ECOBOARD         

≥ 15


Solid construction board ≥ 60 x 160


Mineral wool (Ultimate)≥ 160
Outside

AGEPAN® DWD protect 

16

Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions. Please observe the processing instructions as well as the design notes and boundary conditions of the general building authority test certificates (abP).