2711

Construction type for installing a structural enclosing wooden post-and-beam construction of fire resistance class F 60-B (REI 60) acccording to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.


Construction ExampleProductThickness (mm)
InsideGypsum board  ≥ 12,5


AGEPAN® THD Install 

  ≥ 40


AGEPAN® OSB 3 ECOBOARD          

  ≥15


Solid construction timber   ≥ 60 x 140


Mineral wool (Klemmrock)  ≥ 140
Outside

AGEPAN® DWD protect

16

Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions.