
2155
Construction type for installing a structural enclosing wooden post-and-beam construction of fire resistance class F 60-B (REI 60) acccording to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.
Construction Example | Product | Thickness (mm) |
Inside | Gypsum board | ≥ 12,5 |
AGEPAN® THD Install | ≥ 40 | |
AGEPAN® OSB 3 ECOBOARD | ≥15 | |
Solid construction timber | ≥ 60 x 140 | |
Mineral wool (Klemmrock) | ≥ 140 | |
Outside | AGEPAN® UDP T+G
| ≥ 22 |
Documents
[EN] Brochure AGEPAN SYSTEM13.96 MB
[EN] AGEPAN UDP T+G - Technical data sheet947.24 KB
[EN] AGEPAN THD Install - Technical data sheet5.11 MB
[EN] AGEPAN OSB 3 ECOBOARD - Technical data sheet1.32 MB
[EN/DE] DOP_AGEPAN_OSB3_ECOBOARD_n.3.661.03.14_Nettgau_DE-EN389.78 KB
[EN/DE] DOP_AGEPAN_THD_Install_n.4.662.07.01_Meppen_DE-EN301.08 KB
DOP_AGEPAN_UDP_n.4.662.01.05_Meppen_DE-EN518.97 KB
Where to buy