Design for erecting a supporting, space-enclosing wall structure consisting of a stud frame with required cavity insulation as well as inner and outer lining for achieving fire resistance class REI 45 according to DIN EN 13501-2: 2010-02 for one-sided fire exposure from the external wall side.

Construction ExampleProductThickness (mm)
Inside

AGEPAN® OSB 3 ECOBOARD

≥15


Solid construction timber (KVH)

≥60 x 160


Cellulose (Isocell)≥160


AGEPAN® THD Putz 050    

≥60
OutsideMineral plastering system

10


Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions as well as the design notes and boundary conditions of the general building authority test certificates (abP).