2156

Design for erecting a supporting, space-enclosing timber stud wall construction of fire resistance class F 90-B (REI 90) acconrding to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.

Construction ExampleProductThickness (mm)
InsideGypsum board≥ 12,5


AGEPAN® THD Install

≥ 40


AGEPAN® OSB 3 ECOBOARD≥ 15


KVH

≥ 60 x 140


Mineral wool (Klemmrock)

≥ 140


AGEPAN® THD Putz 050  

≥ 40 
OutsideMineral plastering system

10


Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions.