2156
Design for erecting a supporting, space-enclosing timber stud wall construction of fire resistance class F 90-B (REI 90) acconrding to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.
Construction Example | Product | Thickness (mm) |
Inside | Gypsum board | ≥ 12,5 |
AGEPAN® THD Install | ≥ 40 | |
AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
KVH | ≥ 60 x 140 | |
Mineral wool (Klemmrock) | ≥ 140 | |
AGEPAN® THD Putz 050 | ≥ 40 | |
Outside | Mineral plastering system | 10 |
Documents
[EN] Brochure AGEPAN SYSTEM5.36 MB
[EN] AGEPAN THD Install - Technical data sheet5.11 MB
[EN] AGEPAN THD Putz 050 - Technical data sheet1.21 MB
[EN] AGEPAN OSB 3 ECOBOARD - Technical data sheet1.32 MB
[EN/ES] DOP_OSB3_ECOBOARD_n.3.661.03.14_Nettgau_DE-EN391.14 KB
[EN/DE] DOP_AGEPAN_THD_Putz050_n.4.662.05.04_Meppen_DE-EN659.91 KB