2156
Design for erecting a supporting, space-enclosing timber stud wall construction of fire resistance class F 90-B (REI 90) acconrding to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.
Construction Example | Product | Thickness (mm) |
Inside | Gypsum board | ≥ 12,5 |
AGEPAN® THD Install | ≥ 40 | |
AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
KVH | ≥ 60 x 140 | |
Mineral wool (Klemmrock) | ≥ 140 | |
AGEPAN® THD Putz 050 | ≥ 40 | |
Outside | Mineral plastering system | 10 |
Documents
[EN] Brochure AGEPAN SYSTEM13.96 MB
[EN] AGEPAN THD Install - Technical data sheet5.11 MB
[EN] AGEPAN THD Putz 050 - Technical data sheet808.61 KB
[EN] AGEPAN OSB 3 ECOBOARD - Technical data sheet1.32 MB
[PT] DoP no. 3 661 03 15_OSB3 ECOBOARD & AGEPAN OSB3 ECOBOARD376.47 KB
[EN/DE] DoP no. 4 662 05 05_AGEPAN®THD Putz 050662.48 KB
Where to buy