2535

Design for the erection of a supporting, space-enclosing timber stud wall construction with sound insulation requirements according to DIN 4109, RW,P = 50 dB and a fire resistance class F-90-B according to DIN 4102-2:1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation and internal and external lining.

Construction ExampleProductThickness (mm)
InsideGypsum board≥ 12,5


AGEPAN® THD Install

≥ 60


AGEPAN® OSB 3 ECOBOARD≥ 15


Solid construction timber

≥ 60 x 140


Mineral wool (Klemmrock)

≥ 140


AGEPAN® THD Putz 050  

≥ 40 

Outside
AGEPAN® THD T+G
and/or 
AGEPAN® THD Putz 050

≥ 40 


Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please note the processing instructions.