Fire Protection F 30-B AGEPAN® THD install / AGEPAN® THD Putz + rock wool
Design for erecting a supporting, space-enclosing timber stud wall construction of fire resistance class F 30-B acconrding to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.
Specifications
| Construction Example | Product | Nominal Thickness (mm) |
|---|---|---|
| Inside | Gypsum board | ≥ 12,5 |
| AGEPAN® THD install | ≥ 40 | |
| AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
| KVH | ≥ 60 x 140 | |
| Rock wool (Klemmrock) | ≥ 140 | |
| AGEPAN® THD etics X | ≥ 60 | |
| Outside | Mineral plastering system | 10 |
| Inside | |
|---|---|
| Product | Gypsum board |
| Thickness | ≥ 12,5 |
| Product | AGEPAN® THD install |
| Thickness | ≥ 40 |
| Product | AGEPAN® OSB 3 ECOBOARD |
| Thickness | ≥ 15 |
| Product | KVH |
| Thickness | ≥ 60 x 140 |
| Product | Rock wool (Klemmrock) |
| Thickness | ≥ 140 |
| Product | AGEPAN® THD etics X |
| Thickness | ≥ 60 |
| Product | Mineral plastering system |
| Thickness | 10 |
| Outside |
Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions.