Sound insulation construction external wall 50 dB
Type of construction for the erection of a load-bearing, room-enclosing timber stud wall construction with sound insulation requirements according to DIN 4109, RW,P = 50 dB and a fire resistance class F 90-B according to DIN 4102-2:1977-09. Consisting of a KVH stud frame with a required compartment insulation as well as an inner and outer cladding.
Specifications
| Construction Example | Product | Nominal Thickness (mm) |
|---|---|---|
| Inside | Gypsum board | ≥ 12,5 |
| AGEPAN® THD install | ≥ 60 | |
| AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
| Solid construction timber | ≥ 60 x 140 | |
| Mineral wool (Klemmrock) | ≥ 140 | |
| AGEPAN® THD Putz 050 | ≥ 40 | |
| Outside | AGEPAN® THD cover X and/or AGEPAN® THD etics X | ≥ 40 |
| Inside | |
|---|---|
| Product | Gypsum board |
| Thickness | ≥ 12,5 |
| Product | AGEPAN® THD install |
| Thickness | ≥ 60 |
| Product | AGEPAN® OSB 3 ECOBOARD |
| Thickness | ≥ 15 |
| Product | Solid construction timber |
| Thickness | ≥ 60 x 140 |
| Product | Mineral wool (Klemmrock) |
| Thickness | ≥ 140 |
| Product | AGEPAN® THD Putz 050 |
| Thickness | ≥ 40 |
| Product | AGEPAN® THD cover X and/or AGEPAN® THD etics X |
| Thickness | ≥ 40 |
| Outside |
Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please note the processing instructions.