Fire protection F 30-B AGEPAN® UDP N+F + rock wool
Construction type for installing a structural enclosing wooden post-and-beam construction of fire resistance class F 30-B acccording to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure.

Specifications
Construction Example | Product | Nominal Thickness (mm) |
---|---|---|
Inside | Gypsum board | ≥ 12,5 |
AGEPAN® THD Install | ≥ 40 | |
AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
Solid construction timber | ≥ 60 x 140 | |
Rock wool (Klemmrock) | ≥ 140 | |
Outside | AGEPAN® UDP T+G | ≥ 22 |
Inside | |
---|---|
Product | Gypsum board |
Thickness | ≥ 12,5 |
Product | AGEPAN® THD Install |
Thickness | ≥ 40 |
Product | AGEPAN® OSB 3 ECOBOARD |
Thickness | ≥ 15 |
Product | Solid construction timber |
Thickness | ≥ 60 x 140 |
Product | Rock wool (Klemmrock) |
Thickness | ≥ 140 |
Product | AGEPAN® UDP T+G |
Thickness | ≥ 22 |
Outside |
Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions.
Where to buy
Wide network of specialized distributors, available to receive your orders